What was found
FOUND CRACK ON ANGLE AT R MLG DOOR FWD JAMB. NEW ANGLE FABRICATED AND INSTALLED IAW SRM52-05D FIG 811D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CRACK ON ANGLE AT R MLG DOOR FWD JAMB. NEW ANGLE FABRICATED AND INSTALLED IAW SRM52-05D FIG 811D.