DURING HMV EXFOLIATION CORROSION WAS FOUND ON FLOOR PANEL SUPPORT STA Y=255 X=34 FWD WET AREA. FLOOR SUPPORT WAS REPLACED IAW DOUGLAS DWG 5930544.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HMV EXFOLIATION CORROSION WAS FOUND ON FLOOR PANEL SUPPORT STA Y=255 X=34 FWD WET AREA. FLOOR SUPPORT WAS REPLACED IAW DOUGLAS DWG 5930544.