What was found
REPAIR RT ELEVATOR ANTI-FLOAT TAB DUE TO PRESENCE OF WATER IN HONEYCOMB STRUCTURE. WATER IN HONEYCOMB STRUCTURE REMOVED IAW SRM 51-70-2 PAR 6C. TAB WAS BALANCED IAW SRM 55-20-2D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REPAIR RT ELEVATOR ANTI-FLOAT TAB DUE TO PRESENCE OF WATER IN HONEYCOMB STRUCTURE. WATER IN HONEYCOMB STRUCTURE REMOVED IAW SRM 51-70-2 PAR 6C. TAB WAS BALANCED IAW SRM 55-20-2D.