DURING BLEND OUT, FOUND ELONGATED HOLES ON C2 DOOR JAMB BEAM. ELONGATED HOLE WERE DRILLED UP IAW SRM 51-10-4. BUSHINGS WERE FABRICATED IAW ERA 471657-14 REV ORIG. BUSHINGS WERE INSTALLED IAW ERA 471657-14 REV ORIG. REPAIR WAS IDENTIFIED IAW PS 900-5-1 NR 4.