What was found
A 0.562 INCH CRACK ON FUSELAGE SKIN AT STA Y=175 ON THE WD UPPER CORNER AT THE FWD SERVICE DOOR JAMB. CRACK WAS REMOVED IAW SRM 53-05 FIG 112. NO CRACKS FOUND. INSTALLED REPAIR PARTS IAW SRM 53-05 FIG 112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A 0.562 INCH CRACK ON FUSELAGE SKIN AT STA Y=175 ON THE WD UPPER CORNER AT THE FWD SERVICE DOOR JAMB. CRACK WAS REMOVED IAW SRM 53-05 FIG 112. NO CRACKS FOUND. INSTALLED REPAIR PARTS IAW SRM 53-05 FIG 112.