What was found
EXFOLIATION CORROSION ON LOWER BEAM STA Y=1155-1212 AT AFT CARGO COMP DOOR JAMB. BEAM WAS REPAIRED IAW SRM'S 51-30-5, 51-10-3, AND 53-05 FIG 123.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXFOLIATION CORROSION ON LOWER BEAM STA Y=1155-1212 AT AFT CARGO COMP DOOR JAMB. BEAM WAS REPAIRED IAW SRM'S 51-30-5, 51-10-3, AND 53-05 FIG 123.