What was found
FOUND OVERWING EMERGENCY LIGHTS INTERIOR AND ESCAPE PATH LIGHTS INOP FROM 27-38. FOUND BLOWN FUSES IN EMERGENCY LIGHT CHARGER ASSY B5-211 AND B5-212- REPLACED FUSES- FOUND BAD WIRE UNDER SEAT 28 AND BAD LIGHT SOCKET AT 37399262 R & R LIGHT ASSYS AT SEATS 28 AND 37. REPAIRED WIRE AND REPLACED UNDER SEAT HARNESS AT 37- OPS CKS GOOD.