What was found
DURING MAINTENANCE CHECK FOUND EMERGENCY EXIT LIGHTS OUT FROM ROW 31-36 INOP. FOUND A QUICK DISCONNECT BETWEEN 36D AND 37D BROKEN. REPAIRED QUICK DISCONNECT. OPERATIONAL CHECK OF LIGHTS IS NOW GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE CHECK FOUND EMERGENCY EXIT LIGHTS OUT FROM ROW 31-36 INOP. FOUND A QUICK DISCONNECT BETWEEN 36D AND 37D BROKEN. REPAIRED QUICK DISCONNECT. OPERATIONAL CHECK OF LIGHTS IS NOW GOOD.