What was found
DURING HMV FOUND A 1 INCH DENT AT STA 237 L-18-L ON EXISTING REPAIR. FOUND DENT IN REPAIR DOUBLER TO BE OUT OF LIMITS DUE TO CREASE. FOUND FORMER STA 237 L18L -17L DENTED AND BENT. REMOVED, OBTAINED AND INSTALLED NEW FORMER 9911524U3 IAW SRM 51-30-2, 51-30-5, 51-30-4. REMOVED EXISTING REPAIR DOUBLER AND FILLE, FABRICATED AND INSTALLED NEW REPAIR PARTS IAW SRM 53-04 FIG 12B, SHT 34.