What was found
ON CLIMBOUT, FLT ATTENDANT REPORTED BURNING ODOR COMING FROM AIR CONDITIONING SYSTEM, NO SMOKE WAS VISIBLE. RT PACK WAS SHUTDOWN, ODOR DISSIPATED. INSPECTED PACK, ALL NORMAL. PERFORMED DUCT BURNOUT, RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON CLIMBOUT, FLT ATTENDANT REPORTED BURNING ODOR COMING FROM AIR CONDITIONING SYSTEM, NO SMOKE WAS VISIBLE. RT PACK WAS SHUTDOWN, ODOR DISSIPATED. INSPECTED PACK, ALL NORMAL. PERFORMED DUCT BURNOUT, RETURNED TO SERVICE.