Service difficulty report · Sensor · Doug MD88

Difficulty date
March 30, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N923DL
Make and model
Doug MD88
Aircraft serial
49705
Part
Sensor
Condition
Out Of Adjust
Location
Access Compt Dr
Stage of operation
CL
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACCESS COMPT DOOR LIGHT ILLUMINATED IMMEDIATELY AFTER T/O. AIRCRAFT WOULDN'T PRESSURIZE. VISUAL INSPECTION CONFIRMED COMPT DOOR PROPERLY CLOSED. PRESSURIZED A/C TO 6.25 PSI DIFF, OPS NORMAL. DOOR WARNING SYS DEFERRED, ADJUSTED PROX SENSOR.