What was found
ON DESCENT INTO GRR, GOT LEFT ENG OIL STRAINER CLOG MSG. PERFORMED POM PROCEDURES, LIGHT DID NOT EXTINGUISH. PERFORMED POM PROCEDURES AND SHUT LEFT ENG DOWN AND DECLARED EMERGENCY. FOUND CARBON IN FILTER. REPLACED AND PERFORMED ENGINE RUN-UP, NO ADDITIONAL CARBON FOUND.