What was found
AT FL160, RT HYD QTY WENT TO 2. PRESSURE WAS OK. FOUND RESERVOIR OVERFILL BOTTLE FULL. DISCONNECTED RT MAIN GEAR ACTUATOR AND CYLINDER NUMEROUS TIMES FOUND THIN FILM ON SHAFT PER TML. RECOMMENDED RT HYS RESV AND RT MLG ACTUATOR 448555. REMOVED AND REPLACED HYD RESVOIR IAW M/M. LEAK CHECK OK AND SERVICED. ALSO SEE ITEM07 FOR RT ACTUATOR FOR REFERENCE.