What was found
LT HYDRAULIC PRESSURE WENT TO ZERO SHORTLY AFTER TAKEOFF. FOLLOWED POM PROCEDURE BUT LT PRESSURE WOULD NOT RETURN. AFTER A FEW MINUTES RT HYD TEMP HI MSG CAME ON. REPLACED LT ENG HYD PUMP AND FILTERS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT HYDRAULIC PRESSURE WENT TO ZERO SHORTLY AFTER TAKEOFF. FOLLOWED POM PROCEDURE BUT LT PRESSURE WOULD NOT RETURN. AFTER A FEW MINUTES RT HYD TEMP HI MSG CAME ON. REPLACED LT ENG HYD PUMP AND FILTERS.