Service difficulty report · Lines · Doug MD9030

Difficulty date
April 30, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N906DA
Make and model
Doug MD9030
Aircraft serial
53386
Part
Lines
Condition
Chafed
Location
Rt Hyd Syst
Stage of operation
CR
Nature of condition
K, J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT HYD QTY DECREASED TO 6 QTS IN-FLIGHT. TURNED OFF RT HYD PUMP IAW CHECK LIST. QTY/PRESSURE HELD THROUGH CONFIGURATION THEN WENT TO QTY 2 PRESSURE 5. FOUND PRESSURE AND RETURN LINES CHAFED ON AUXILIARY HYDRAULIC PUMP. REPLACED SAME.