What was found
FRAME AS STA 1240, S-26R IS BENT. CUT OUT BENT PORTION. FABRICATED AND INSTALLED FRAME SECTION REPAIR 10.4 X 2.5 INCHES FROM 7075-T6 .080 IAW B757 SRM 51-70-11, 51-20-01 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AS STA 1240, S-26R IS BENT. CUT OUT BENT PORTION. FABRICATED AND INSTALLED FRAME SECTION REPAIR 10.4 X 2.5 INCHES FROM 7075-T6 .080 IAW B757 SRM 51-70-11, 51-20-01 AND 51-40-02.