What was found
FRAME AS STA 1440 , S-26L IS BENT. CUT OUT BENT PORTION. FABRICATED AND INSTALLED FRAME SECTION REPAIR 10.5 X 2.5 INCHES FROM 7075-T6 .063 AND CLIP P/N 3.30 X 1.75 INCHES FROM BAC1518-769 IAW B757 SRM 51-70-11, 51-20-01 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AS STA 1440 , S-26L IS BENT. CUT OUT BENT PORTION. FABRICATED AND INSTALLED FRAME SECTION REPAIR 10.5 X 2.5 INCHES FROM 7075-T6 .063 AND CLIP P/N 3.30 X 1.75 INCHES FROM BAC1518-769 IAW B757 SRM 51-70-11, 51-20-01 AND 51-40-02.