What was found
AFT PIT STA 1320 S-25R - S-26R FRAME DENTED. REMOVED PREVIOUS REPAIR. FABRICATED AND INSTALLED FRAME REPAIR 26 X 5 INCHES FROM 7075-T6. 071 IAW B757 SRM 51-70-11 FIG 1 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT STA 1320 S-25R - S-26R FRAME DENTED. REMOVED PREVIOUS REPAIR. FABRICATED AND INSTALLED FRAME REPAIR 26 X 5 INCHES FROM 7075-T6. 071 IAW B757 SRM 51-70-11 FIG 1 AND 51-40-02.