What was found
FWD CARGO FLOOR SUPPORT HAS DENTS BETWEEN STA 580 & 600 AT LBL 2. CUT OUT DENTED SECTION. FABRICATED AND INSTALLED REPAIR 40.80 INCHES AND 2 EA SPLICES 10.00 X 1.10 X .75 AND 10.0 X 1.10 X .65 FROM BAC1517-2226 IAW B757 SRM 53-00-53, 51-70-11, 51-70-12, 51-20-01 AND 51-40-02.