What was found
CORROSION ON FAIRING FRAME AT BS 900 LBL 25 TO RBL 25. CUT OUT CORRODED SECTION OF FRAME. FABRICATED AND INSTALLED REPAIR ANGLE 44-1/4" BY 2-3/4" BY 1-1/4" FROM BAC1505-100403 7075-T6 IAW B757 SRM 51-70-12 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FAIRING FRAME AT BS 900 LBL 25 TO RBL 25. CUT OUT CORRODED SECTION OF FRAME. FABRICATED AND INSTALLED REPAIR ANGLE 44-1/4" BY 2-3/4" BY 1-1/4" FROM BAC1505-100403 7075-T6 IAW B757 SRM 51-70-12 FIG 1.