What was found
CORROSION AT CABIN FLOOR SUPPORT BS 1676 BL 0. REMOVED CORROSION. SHIM OUT OF LIMITS. FABRICATED AND INSTALLED SHIM 2 X 15.75 INCHES FROM 7075-T6 .125" IAW B757 SRM 51-30-01, 51-20-01 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT CABIN FLOOR SUPPORT BS 1676 BL 0. REMOVED CORROSION. SHIM OUT OF LIMITS. FABRICATED AND INSTALLED SHIM 2 X 15.75 INCHES FROM 7075-T6 .125" IAW B757 SRM 51-30-01, 51-20-01 AND 51-40-02.