What was found
FOUND CORROSION ON FRAME AT L-1 DOOR CUTOUT BS 160 WL-208. MECHANICALLY REMOVED CORROSION. ORIGINAL THICKNESS .125, MATERIAL LOSS .025. FOUND WITHIN LIMITS IAW MD-88 SRM 53-01 FIG 1. TREATED AND PRIMED IAW MD-88 SRM 51-10-3D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON FRAME AT L-1 DOOR CUTOUT BS 160 WL-208. MECHANICALLY REMOVED CORROSION. ORIGINAL THICKNESS .125, MATERIAL LOSS .025. FOUND WITHIN LIMITS IAW MD-88 SRM 53-01 FIG 1. TREATED AND PRIMED IAW MD-88 SRM 51-10-3D.