What was found
DENT IN FS 1322, L-20R REQUIRES PERMANENT REPAIR. REMOVED TEMP EXISTING DOUBLER. FABRICATED AND INSTALLED DOUBLER 7" BY 4-3/4" FROM 2024-T3 .063" AND FINGER DOUBLER 8-5/8" BY 6-3/4" FROM 2024-T3 .025" IAW DC-9/MD-80 SRM 51-30-2 PG 1, 53-04D FIG 38, AND 51-10-3D PG 1.