What was found
DENT IN SKIN FS 229, L-17L TO L-18L REQUIRES PERMANENT REPAIR. REMOVED TEMP EXISTING DOUBLER PER DELTA ERA 365805-14. FABRICATED AND INSTALLED DOUBLER 17-1/2" BY 16-1/2" FROM 2024-T3 .063" AND FILLER 14" BY 13" FROM 2024-T3 .050" ALUM SHEET AND 2 FINGER DOUBLERS 8-3/8" BY 2-3/4", 6-1/4" BY 2-7/8" FROM 2024-T3 .025" IAW DELTA ERA 096199-14 REV IR DC-9/MD-80 SRM 51-30-1, 51-30-2, 51-30-5, 53-04D FIG 12B, AND 51-10-3D.