What was found
SMALL DENT AT FS 313 LT LONGERON 17L. DENT OUT OF LIMITS IAW SRM 53-04D TABLE C. FABRICATED AND INSTALLED REPAIR DOUBLER 7.5 INCHES X 7.5 INCHES FROM 2024-T3 .032 INCHES IAW SRM 51-10-3D, 51-30-2 AND 53-04D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SMALL DENT AT FS 313 LT LONGERON 17L. DENT OUT OF LIMITS IAW SRM 53-04D TABLE C. FABRICATED AND INSTALLED REPAIR DOUBLER 7.5 INCHES X 7.5 INCHES FROM 2024-T3 .032 INCHES IAW SRM 51-10-3D, 51-30-2 AND 53-04D.