What was found
CORROSION BETWEEN 5 AND 7 O'CLOCK POSITION FRAME STA 1418, VENTRAL STAIRWAY. CUT OUT CORRODED SECTION OF WEB FRAME. FABRICATED AND INSTALLED WEB REPAIRS 28" BY 6.25 FROM 7075-T6 .063" AND 6.25" BY 5.5" FROM 7075-T6 .071" IAW DC-9/MD-80 SRM 53-14-4 FIG 1, 51-70-4 FIG 1 AND 51-30-2.