What was found
LIGHTNING STRIKE LT FS 440 1/2" ABOVE L-26L. BLENDED LIGHTNING STRIKE, CUT OUT WORN AREA, FABRICATED AND INSTALLED 3 REPAIR DOUBLERS 1" DIAMETER, 8" BY 1-5/8" BY 9" AND 5-5/8' BY 5-5/8' BY 5-1/4" FROM 2024-T3 .050" AND FINGER DOUBLER 7-1/4" BY 4-3/8" BY 8-3/8" FROM 2024-T3 .025" IAW DC-9/MD-80 SRM 53-04D FIG 38, VIEW V AND 51-10-3D.