What was found
CORROSION (HEAVY) ON AFT PIT FRAME SHEAR TIE AT FS 1480 BETWEEN S-29L AND S-30. FABRICATED AND INSTALLED SHEAR TIE 4-3/4" BY 1" BY 3-1/2" FROM 7075-T6 .050" AT FS 1480 BETWEEN S-29L AND S-30 IAW BOEING DRAWING 140N2002 AND 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION (HEAVY) ON AFT PIT FRAME SHEAR TIE AT FS 1480 BETWEEN S-29L AND S-30. FABRICATED AND INSTALLED SHEAR TIE 4-3/4" BY 1" BY 3-1/2" FROM 7075-T6 .050" AT FS 1480 BETWEEN S-29L AND S-30 IAW BOEING DRAWING 140N2002 AND 51-20-01.