What was found
HEAVY CORROSION ON MAIN CABIN FLOORBEAM UPPER CAP AT BS 720 LBL 4. FABRICATED AND INSTALLED FLOORBEAM REPAIR 12" BY 1.6" FROM BAC1505-100617, 9" BY .7" FROM 7075-T6 .125", 11.25" BY .9" FROM 7075-T6 .063", 11.25" BY .9" FROM 7075-T6 .090", AND 9" BY 1/2" FROM 7075-T6 .125" IAW B757 SRM 53-10-51D, 51-40-05 AND 51-20-01.