What was found
LIGHTNING STRIKE ON FUSELAGE SKIN AT BS 457 S-7R - S-8R. CUT OUT LIGHTNING STRIKE AREA. FABRICATED AND INSTALLED EXTERNAL REPAIR DOUBLER 10.4" BY 9" FROM 2024-T3 .071" IAW B757 SRM 53-00-01 FIG 201 REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LIGHTNING STRIKE ON FUSELAGE SKIN AT BS 457 S-7R - S-8R. CUT OUT LIGHTNING STRIKE AREA. FABRICATED AND INSTALLED EXTERNAL REPAIR DOUBLER 10.4" BY 9" FROM 2024-T3 .071" IAW B757 SRM 53-00-01 FIG 201 REPAIR 2.