What was found
CORROSION ON GALLEY FLOOR AT BS 1720 - BL 0 TO BL 8R CABIN COMPARTMENT. FABRICATED AND INSTALLED REPAIR DOUBLER 18-1/2" BY 7-1/2" FROM 2024-T3 .063" BAC1517-2226 IAW B757 SRM 51-10-02, 53-00-51, 51-20-01, AND 53-60-51 FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON GALLEY FLOOR AT BS 1720 - BL 0 TO BL 8R CABIN COMPARTMENT. FABRICATED AND INSTALLED REPAIR DOUBLER 18-1/2" BY 7-1/2" FROM 2024-T3 .063" BAC1517-2226 IAW B757 SRM 51-10-02, 53-00-51, 51-20-01, AND 53-60-51 FIG 201.