What was found
FLOOR SUPPORT STRINGER HAS DRILL BIT DAMAGE BS 594 LBL 11 FWD CARGO COMPT. CUT OUT DRILLED SECTION OF FLOOR SUPPORT, FABRICATED AND INSTALLED 2 ANGLES 9" BY 1" BY 1" FROM 7075-T6 .050" AND 2 ANGLES 10" BY 1" BY 1" FROM 2024-T3 .040" IAW B757 SRM 51-70-12, FIG 1.