What was found
FOUND CORROSION AFT CARGO FLOOR PANEL SPLICE AT BS 1510. REPAIRED CORRODED SPLICE BY FABRICATING AND INSTALLING NEW SPLICE 1-3/4 BY 40 FROM BAC1505-100766 7075-T6 IAW B757 SRM 51-20-1, 51-40-02 AND DWG 453N1611.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION AFT CARGO FLOOR PANEL SPLICE AT BS 1510. REPAIRED CORRODED SPLICE BY FABRICATING AND INSTALLING NEW SPLICE 1-3/4 BY 40 FROM BAC1505-100766 7075-T6 IAW B757 SRM 51-20-1, 51-40-02 AND DWG 453N1611.