As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND CORROSION AFT CARGO BS 1445.6 TO BS 1530 LT TRANSITION SIDE PANEL CORROSION ON GILL LINER ATTACH AREA AND FLOOR PANEL ATTACH AREA. FABRICATED AND INSTALLED SPLICE PLATE 4" BY 6" BY 12" AND TRANSITION PANEL 654N0244-1033 (SEE ROUTINE 3770) IAW B757 SRM 51-10-02 AND 51-40-05 FIG 3, AMM 53-88-01-801.