What was found
FOUND CORROSION ON FLOORBEAM UPPER CAP AT BS 1681 LBL 24. CUT OUT CORRODED AREAS. FABRICATED AND INSTALLED REPAIR DOUBLER 26.5 BY 2 FROM 2024-T3 .080 AND 3 FILLERS FROM 2024-T3 .071 IAW B757 SRM 53-60-51 FIG 201, 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON FLOORBEAM UPPER CAP AT BS 1681 LBL 24. CUT OUT CORRODED AREAS. FABRICATED AND INSTALLED REPAIR DOUBLER 26.5 BY 2 FROM 2024-T3 .080 AND 3 FILLERS FROM 2024-T3 .071 IAW B757 SRM 53-60-51 FIG 201, 51-20-01.