What was found
S/O NR 291043, N/R 22832, FOUND DENT ON MAIN FRAME UPPER CAP (UNDER FLOOR SUPPORT Z CHANNEL) AT BS 1500 RBL 11 IN AFT PIT. REPAIRED BY CUTTING OUT DENTED AREA, HFEC CUT OUT IAW NTM 51-00-19 PT. 6, NO RELEVANT INDICATIONS. FABRICATED AND INSTALLED CHANNEL REPAIR 8.5 X 2 X .5 FROM 7075-T6 .063 IAW SRM 53-00-57 FIG. 201, 51-20-01 AND 53-00-07.