What was found
DURING SCHEDULED INSPECTION, FOUND AFT CARGO DOOR CUTOUT, INTERNAL BEARSTRAP CORRODED AT 2.5" ABOVE S24R TO 2" BELOW S-24R FWD OF BS 847 FRAME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION, FOUND AFT CARGO DOOR CUTOUT, INTERNAL BEARSTRAP CORRODED AT 2.5" ABOVE S24R TO 2" BELOW S-24R FWD OF BS 847 FRAME.