What was found
DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H FR 68 #1 DOORSTOP FITTING BOTTOM INBD HOLE HAS A CRACK INDICATION IN THE FRAME LAYER AT THE 6 O'CLOCK POSITION. S/O 193145 N/R 44077