What was found
DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FOUND RH WING UPPER SURFACE, RIB 6 AND BETWEEN STR. 4 - 9 HAS MULTI AREAS OF CORROSION AROUND MULTI FASTENERS. S/O 193150 NR 01366554 HAECO OPS 26250
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FOUND RH WING UPPER SURFACE, RIB 6 AND BETWEEN STR. 4 - 9 HAS MULTI AREAS OF CORROSION AROUND MULTI FASTENERS. S/O 193150 NR 01366554 HAECO OPS 26250