What was found
FOUND CREASE 28" AFT OF L-4 DOOR AT SILL LEVEL. CUT OUT CREASED AREA IAW B757 SRM 53-00-01 FIG 201. HFEC FOR CRACKS IAW D6-34N301-6-51-00P6. FABRICATED AND INSTALLED REPAIR DOUBLER X 4.75" FROM 2024-T3 0.090" IAW B757 SRM 53-00-01 FIG 201 REPAIR 3.