What was found
FUSELAGE FAIRING PANEL ATTACH NUTPLATES FAIL DRAG TORQUE OF 12-15 IN POUNDS. NO NOTED TORQUE ON NUTPLATES. EVALUATED ACFT ACCESS PANEL NUTPLATES FOR DEFECTS. INSTALLED NUT PLATES IAW 680 MM 51-40-03. INSTALLED PANELS IAW 680 MM. INSTALLED NUTPLATES IN RT LWR PYLON IAW 680 MM. INSTALLED RT PYLON LWR ACCESS PANELS IAW 680 MM. CLOSED RT ENGINE COWLING. 16 NUTPLATE SCREWS INSTALLED IAW ENGINEERING ORDER 680-0100, 15 CR NUMBER 099500 REF DRAWING 6900056.