As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING TAKEOFF POWER APPLICATION, LT GENERATOR TRIPPED OFF LINE (LOW SPEED ABORT). VISUALLY INSPECTED LH GENERATOR WIRING. ALL CONNECTIONS TIGHT. RAN BOTH ENGINES WITH GENERATOR SELECTED ON. CYCLED RT GEN OFF AND VERIFIED LT TOOK LOAD ON AMP METER. GENERATOR SYSTEM OPS CHECK GOOD I.A.W. 560 M/M 24-31-01.