Service difficulty report · Thermal Switch · Gulstm 200

Difficulty date
October 24, 2007
Submitted
November 7, 2007
Operation
Air carrier
Aircraft
N702QS
Make and model
Gulstm 200
Aircraft serial
070
Aircraft time
3,887 hours, 2,381 cycles
Engine
Pwc PW306A
Part
Thermal Switch
Part number
6411801
Part serial
148153
Condition
Inoperative
Location
Engine
Part time
3,887 hours, 2,381 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

JUST AFTER ENGINE RUN-UP GOT LINE PRESSURE HIGH/OVER TEMP WARNING ILLUMINATED. WHEN THROTTLES REDUCED TO IDLE, LIGHT WENT OUT. PERFORMED ENGINE RUN, NO DEFECTS NOTED. CHECKED HP PRSOV VALVES NR 1 & 2 ENGINE; PRESSURE FROM NR 1 ENG HP PRSOV VALVE 25 PSI AND NR 2 ENG 25 PSI. REMOVED REMOVED S/N 0148 AND REPLACED OVERTEMPERATURE SWITCH FWD P/N 641180-1 S/N 0369. AFT TEMP SWITCH S/N 0351 REMOVED S/N 0153 IAW G-200 M.M. CH 21-11-07. NO DEFECTS NOTED. OPS CHECK SATISFACTORY.