What was found
CARGO FIRE WARNING LIGHT COME ON DURING APPROACH. VISUALLY CHECKED THE FWD, UNDERSINK AND AFT SMOKE DETECTORS MOUNTING AREAS FOR SIGN OF BURNED/HEATING PARTS OF THE AC, CHECKED WIRES AND CONNECTORS OF THE SMOKE DETECTORS, NO FAULTS FOUND. CHECKED VISUALLY THE SMOKE DETECTOR AMPLIFIER AND SLIGHTLY TAPPED THE AMPLIFIER, NO FAULT FOUND. CHECKED THE SWITCHES TERMINALS, NO FAULT NOTED. PERFORMED SMOKE DETECTION SYS FUNCTIONAL TEST, CHECKED GOOD, IAW MM ADDENDA ATA 26-11-00. WORK DONE IAW DWG NR A8-8R-100. REFER TO WO SC1823 ITEM 1.9 FOR DETAILS.