What was found
TURNED ON AVIONICS, FMS HAD NO SCREEN (SCREEN BLACK) AND DETECTED SMOKE, LIKE INSULATION BURNING ON WIRES. MET WITH CREW. FMS SMELLS BURNED. FMS CDU BAD ONBOARD AIRCRAFT. REMOVED FMS CDU AND INSTALLED REPAIRED UNIT. OPS CHECK WAS GOOD, UPDATED THE NAV DATABASE TO EFFECTIVE PERIOD ENDING AUG 28/08, ALL WORK DONE IAW CE-560 MM CHAP 34-62-00.