As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
"FLAPS FAIL" MSG ILLUMINATED DURING FLAP RETRACTION. EXTENSION WAS NORMAL UPON DEPRESSING FLAP RESET SWITCH ONEC. FOUND BITE 2 INDICATED. POWERED UP ACFT. NO FLAP EICAS FAULTS NOTED. CYCLED SLATS/ FLAPS 3 TIMES. NO FAULTS NOTED. CONTACTED MCC. NO FAULT HISTORY SINCE JAN 2008. SUSPECT COLD SOAK ISSUE.