As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE RESETTING HYD CONTROL CIRCUIT BREAKER , L T MAIN GEAR EXTENDED AND GREEN DOWN AND LOCKED LIGHT ILLUMINATED. REMOVED AND REPLACED LT MAIN GEAR ACTUATOR WITH RENTAL UNIT IAW MM 32-30-04. OPS AND LEAK CHECK GOOD. INSTALLED UNIT HAS 2089 CYCLES.