What was found
APU RUNNING, WITH BLEED ON AND ENGINES RUNNING, SMOKE ENTERED THE CABIN. REMOVED AND REPLACED APU. SERVICED OIL TO FULL. OPERATIONAL AND LEAK CHECK GOOD. WORK PERFORMED IAW MM 49-10-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU RUNNING, WITH BLEED ON AND ENGINES RUNNING, SMOKE ENTERED THE CABIN. REMOVED AND REPLACED APU. SERVICED OIL TO FULL. OPERATIONAL AND LEAK CHECK GOOD. WORK PERFORMED IAW MM 49-10-00.