What was found
NR 1 RMU SWITCHED ON AND OFF TWICE IN FLIGHT. EACH TIME THIS HAPPENED A STRONG ELECTRICAL ODOR WAS NOTICED. NR 1 COMM CB WAS PULLED. REMOVED RMU AND INSTALLED SERVICEABLE UNIT IAW MM 23-80-01. SYSTEM OPERATIONAL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 RMU SWITCHED ON AND OFF TWICE IN FLIGHT. EACH TIME THIS HAPPENED A STRONG ELECTRICAL ODOR WAS NOTICED. NR 1 COMM CB WAS PULLED. REMOVED RMU AND INSTALLED SERVICEABLE UNIT IAW MM 23-80-01. SYSTEM OPERATIONAL CHECKS GOOD.