What was found
FLAPS FAIL CAS MSG CAME ON AFTER FLAP RETRACTION (FLAPS & SLATS UP). FLAPS WOULD NOT RESET UPON APPROACH, SLATS EXTENDED , FLAPS STAYED AT 0*. FOUND BITES 2, 6, 8. RESET BITES. FOUND EXCESSIVE DEBRIS IN FLAP HANDLE ASSY CLEANED DEBRIS. NO DEFECTS NOTED IN ASSY. REINSTALLED AND CYCLED FLAP. OPS CHECK GOOD AT THIS TIME. MX IAW CE 750 MM 27-50-00.